MHP-Naphtha, middle distillates, VGO hydrotreating

Description

This pilot plant is a dedicated configuration of Vinci Technologies’ MHP platform for naphtha, middle distillates and VGO hydrotreating. It supports catalyst screening, kinetic studies and process development, with controlled feed delivery and product measurement.

Application and objectives

The unit enables researchers to evaluate catalyst activity, selectivity and stability during naphtha,  middle distillates and VGO  hydrotreating. Independent adjustment of liquid feed rate, hydrogen flow, pressure and reactor temperature profile allows the influence of operating conditions to be investigated. Gas and liquid recovery supports product characterisation and material balances.

Feed preparation and catalyst sulphiding

The feedstock is supplied from a tank mounted on a balance through a metering pump equipped with a Coriolis mass flow meter. Hydrogen and nitrogen are regulated through mass flow controllers. A separate DMDS circuit, comprising a weighed tank, metering pump and Coriolis meter, supports catalyst sulphiding according to the selected catalyst’s requirements.

Reaction section

A gas mixer and electric preheater prepare the feed before it enters a down-flow fixed-bed reactor. The configuration accommodates 0.2 L of catalyst in a 0.3 L reactor. A five-zone conduction furnace and multipoint thermowell provide axial temperature control and monitoring.

Separation and product measurement

High- and low-pressure separators recover liquid product from the reactor effluent. Back-pressure regulators control pressure, while level controls regulate liquid transfer. Low-pressure nitrogen is available for stripping. Hydrotreated naphtha, middle distillates and VGO passes through a mass flow meter and an automatic six-vial sampler before collection in a vessel mounted on a balance. Gas effluent is metered and can be connected to the customer’s gas chromatograph.

Operating basis and supervision

Operating limits are 200 barg and 550 °C; actual test conditions depend on the selected catalyst and experimental programme. A PLC, supervision workstation and multi-level safety system provide process control and monitoring.

Features