Description
This pilot plant is a dedicated configuration of Vinci Technologies’ FTS platform for the catalytic conversion of synthesis gas into hydrocarbons, including liquid products and waxes. It supports catalyst screening, kinetic studies and process development, with controlled gas delivery, unconverted gas recycle and separate product recovery.
Application and objectives
The unit enables researchers to evaluate Fischer-Tropsch catalyst activity, selectivity and stability. Independent adjustment of hydrogen and carbon monoxide flow rates, recycle flow, pressure and reactor temperature allows the influence of operating conditions on CO conversion and hydrocarbon distribution to be investigated. Separate recovery of gas, waxes, liquid hydrocarbons and water supports product characterisation and material balances.
Feed preparation and gas recycle
Hydrogen and carbon monoxide are supplied through high-pressure lines equipped with thermal mass flow controllers. Fresh gases are combined with recycled unconverted gas in a static mixer. A hydraulic piston compressor equipped with Coriolis flow control regulates gas recycle. A heat exchanger using the reactor jacket fluid and an electric preheater bring the combined feed to the required reactor inlet temperature. Nitrogen is available for purging and inerting.
Reaction section
The syngas flows downward through two fixed-bed catalyst tubes housed in a common thermal-oil jacket. The configuration accommodates a stated catalyst loading of 0.5 L. A five-zone furnace and an oil circulation loop equipped with a heater and air cooler provide controlled heating and heat removal for the exothermic reaction. Temperature control supports near-isothermal operation and investigation of the relationship between reactor conditions and product selectivity.
Separation and product measurement
Three separation stages recover the different product fractions. A hot high-pressure separator operating at up to 250 °C recovers heavy waxes, while a cold high-pressure separator at 10 °C condenses water and lighter hydrocarbons. A cold low-pressure three-phase separator separates gas, water and liquid hydrocarbons. An electronic high-pressure back-pressure regulator and a manual low-pressure back-pressure regulator control pressure. Heated wax handling maintains fluidity during transfer and collection. Coriolis meters measure wax, liquid hydrocarbon, water and gas flows, while separate recovery vessels mounted on balances monitor product collection. Hydrocarbon and aqueous products each have an automatic four-vial sampler. A connection is provided for online gas chromatography.
Operating basis and supervision
Operating limits are 45 barg and 350 °C, with a nominal production capacity of 1 kg/day. The stated GHSV range is 2,000–3,000 h⁻¹ with gas recycle; actual test conditions and production depend on the selected catalyst and experimental programme. A PLC-based automation system, supervision workstation and safety system provide process control, data logging, alarms and protective functions.