Catalytic reforming of naphtha and suitable light hydrocarbons
Description
This pilot plant is a dedicated configuration of Vinci Technologies’ PCC — Petrochemical Catalytic Conversion platform for catalytic reforming of naphtha and suitable light hydrocarbons. It supports catalyst screening, kinetic studies and process development, with controlled feed delivery and gas and liquid product measurement.
Application and objectives
The unit enables researchers to evaluate catalyst activity, selectivity and stability for high-octane reformate, aromatics and hydrogen production. It accommodates Pt–Re, Pt–Ir, Pt–Sn and advanced trimetallic catalysts supported on chlorided alumina. Independent adjustment of liquid feed rate, hydrogen flow, pressure and reactor temperature profile allows the influence of operating conditions to be investigated. Long-duration tests support assessment of catalyst deactivation and the effects of chloride and moisture balance.
Feed preparation and vaporisation
The feedstock is supplied from a nitrogen-blanketed tank mounted on a balance through a high-pressure metering pump equipped with a Coriolis mass flow meter. Hydrogen and nitrogen are regulated through thermal mass flow controllers. A static mixer, electric vaporiser and preheating section prepare the combined feed before it enters the reactor.
Reaction section
The vaporised feed passes through a down-flow fixed-bed reactor accommodating 40 mL of catalyst. A five-zone conduction furnace, with independent temperature control for each zone, provides controlled heating along the catalyst bed and supports a near-isothermal axial temperature profile. The reactor has an internal diameter of 11 mm and a height of 1,000 mm.
Separation and product measurement
High- and low-pressure separators recover liquid reformate from the reactor effluent. Back-pressure regulators control pressure, while level control valves regulate liquid transfer and discharge. Low-pressure nitrogen is available for stripping dissolved gases from the liquid product. Gas and liquid effluents are measured by Coriolis mass flow meters. Reformate passes through an automatic six-vial sampler before collection in a recovery vessel mounted on a balance. A gas connection allows analysis through the customer’s online gas chromatograph.
Operating basis and supervision
Operating limits are 50 barg and 550 °C; actual test conditions depend on the selected catalyst and experimental programme. The stated operating basis includes an LHSV of 1–1.5 h⁻¹ and a hydrogen-to-liquid ratio of 500 NL/L. A CompactLogix PLC, Vinci supervision workstation and multi-level safety system provide process control, data acquisition, alarms and shutdown functions.